Shed roof snow load table

For an unheated, low-risk shed the ASCE 7 method gives a roof snow load of about 0.67 times the ground snow load before slope reduction: 20 psf of roof load at 30 psf ground load, 34 psf at 50. Steep smooth metal roofs shed part of it.

Ce 1.0, Ct 1.2 (unheated), Is 0.8 (Risk Category I). Shingle and resin roofs are treated as non-slippery; the 8/12 column assumes smooth unobstructed metal. Drift, rain-on-snow and sliding snow are not included. General guidance only, not engineering: get your ground snow load from your building department.

Ground loadFlat roof pf2/12 shingle4/12 shingle8/12 metalTotal on 8x10 roof (4/12)
10 psf6.78.06.74.4538 lb
20 psf13.416.013.48.91,075 lb
30 psf20.220.220.213.31,613 lb
40 psf26.926.926.917.72,150 lb
50 psf33.633.633.622.22,688 lb
60 psf40.340.340.326.63,226 lb
70 psf47.047.047.031.13,763 lb
80 psf53.853.853.835.54,301 lb
100 psf67.267.267.244.45,376 lb

Sheds for snow country

Researched picks spread from budget to premium.

Prices change often; the button shows today's price on Amazon.

Other shed reference charts

Frequently asked questions

Is this table enough to choose a shed for heavy snow?

It is a screening tool. Compare the design load for your area with the roof rating a manufacturer publishes, and where there is no published rating, plan to clear the roof after large storms. Drifting against a house or taller wall can multiply the load, so placement matters as much as the number.

This page is researched guidance, not professional engineering, legal or building-code advice. Sizes, loads and permit rules vary by product and by town: check your local code and the kit manufacturer's instructions before you build.